UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Impact (T6) P.8/102.Test Purpose: This test simulates an impact.3.Test Procedure: The test sample cell or component cell is to be placed on a flat surface. A 15.8mm diameter bar is to be placed across the center of the sample. A 9.1kg mass is to be dropped from a height of 61+-2.5cm onto the sample. A cylindrical or prismatic cell is to be impacted with its longitudinal axis parallel to the flat surface and perpendicular to the longitudinal axis of the 15.8mm diameter curved surface lying across the centre of the test sample. A prismatic cell is also to be rotated 90 degrees around its longitudinal axis so that both the wide and narrow sides will be subjected to the impact. Each sample is to be subjected to only a single impact. Separate samples are to be used for each impact. A coin or button cell is to be impacted with the flat surface of the sample parallel to the flat surface and the 15.8mm diameter curved surface lying across its center. SANYO Internal Procedure: As above.4.Test Requirements: External temperature of test batteries does not exceed 170AC and there is no disassembly and no fire within six hours of this test.5.Test Date: 2007/11/126.Test Data :10 PASS20 PASS30 PASS40 PASS50 PASS678PASS910110 PASS120 PASS130 PASS140 PASS150 PASS1617181920Notes: D-Disassembly, F-Fire, 0-No disassembly & no fire After 50cyclesending, infullydischargedstates5859605153126Cell No. Maximum Temperature(7C)OthereventResult Judgement At firstcycle, 50%chargedstates129126131128

参考になったと評価
  6人が参考になったと評価しています。

その他の取扱説明書
3096 view
816 view
868 view
324 view
247 view
もっと見る

このマニュアルの目次

  • 1 .
    Name of SampleConsignorM...
    Name of SampleConsignorManufacturerTest MethodCriterionAppearanceTest DateSample NumberTest ItemsConclusionUnited Nations "Recomenndations on the TRANSPORT OF DANGEROUS GOODS"Black rectangular parallelepiped2008/11/20 - 2008/12/1924Altitude simulation, Th...
  • 2 .
    Presence ofchange----T2:T...
    Presence ofchange----T2:Thermal Shock  (Repetition of high temp.and low temp.)・Crimped part, Gasket (Cell)・Gas Release Vent, Cell Case (Cell)・Finished state of Wound Electrodes (Cell)・Pack (Plastic) Case・Holding Member(Insulator, Insulation Tape, Both Side...
  • 3 .
    (Manual of Tests and Cri...
    (Manual of Tests and Criteria ST/SG/AC.10/11/Rev.4, PartIII,sub-section 38.3)7.56 gAS10E36May.27.2010Nominal voltageWatt-hour rating Lithium ion battery Specification:::Customer Model For battery onlyFor cell onlyE1004664PassPassPassPassPassPassPass−S...
  • 4 .
    7.56 gAS10E36May.27.2010...
    7.56 gAS10E36May.27.2010Nominal voltageWatt-hour rating Lithium ion battery Specification:::Customer ModelE1004664Sanyo Product CodeSanyo ModelF138608043UR18650-3-T0664Certificate of Package Drop Test for Lithium ion battery11.1 V94 Wh
  • 5 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Altitude simulation (T1) P.3/102.Test Purpose: This test simulates air transport under low-pressure conditions.3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa...
  • 6 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Thermal Test (T2) P.4/102.Test Purpose: This test assesses cell and battery seal integrity and internal electrical connections. The test is conducted using rapid and extreme temperature changes...
  • 7 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Vibration (T3) P.5/102.Test Purpose: This test simulates vibration during transport.3.Test Procedure: Cells and batteries are firmly secured to the platform of the vibration machine without disto...
  • 8 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Shock (T4) P.6/102.Test Purpose: This test simulates possible impacts during transport.3.Test Procedure: Test cells and batteries shall be secured to the testing machine by means of a rigid mount...
  • 9 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: External short circuit (T5) P.7/102.Test Purpose: This test simulates an external short circuit.3.Test Procedure: The cell or battery to be tested shall be temperature stabilized so that its exte...
  • 10 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Impact (T6) P.8/102.Test Purpose: This test simulates an impact.3.Test Procedure: The test sample cell or component cell is to be placed on a flat surface. A 15.8mm diameter bar is to be placed ac...
  • 11 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Overcharge (T7) P.9/102.Test Purpose: This test evaluates the ability of a rechargeable battery to withstand an overcharge condition.3.Test Procedure: The charge current shall be twice the manufac...