UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Altitude simulation (T1) P.3/102.Test Purpose: This test simulates air transport under low-pressure conditions.3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa or less for at least six hours at ambient temperature(20+-5 ℃). SANYO Internal Procedure: As above.4.Test Requirements: No mass loss(less than 0.1%),no leakage,no venting,no disassembly,no rupture and no fire,and the voltage retention is not less than 90%. The requirement relating to voltage is not applicable to test batteries at fully discharged states.5.Test Date: 2008/12/26.Test DataBefore test After test Before test After test1 490.68 490.68 0.00 12.81 12.81 100.00PASS2 491.47 491.49 0.00 12.80 12.80 100.00PASS3 490.80 490.77 0.01 12.80 12.80 100.00PASS4 490.97 490.98 0.00 12.81 12.81 100.00PASS5 491.24 491.23 0.000PASS6 491.59 491.61 0.000PASS7 490.71 490.73 0.000PASS8 490.73 490.74 0.000PASS9 491.51 491.52 0.00 12.68 12.68 100.00PASS10 490.62 490.64 0.00 12.69 12.69 100.00PASS11 490.97 490.98 0.00 12.68 12.68 100.00PASS12 491.26 491.29 0.01 12.68 12.68 100.00PASS13 491.31 491.32 0.000PASS14 491.87 491.87 0.000PASS15 491.19 491.21 0.000PASS16 491.25 491.24 0.000PASSNotes: L-Leakage, V-Venting, D-Disassembly, R-Rupture, F-Fire, 0-No leakage, no venting, no disassembly, no rupture & no fireResult Judgement At firstcycle,infullychargedstatesPASSAt firstcycle,infullydischargedstatesAfter 50cyclesending infullychargedstatesAfter 50cyclesending infullydischargedstatesBattery No.Mass(g)Massloss (%)(=<0.1%)Voltage(V)VoltageRetention(%)(=>90%)Otherevent

参考になったと評価
  6人が参考になったと評価しています。

その他の取扱説明書
3096 view
816 view
868 view
324 view
247 view
もっと見る

このマニュアルの目次

  • 1 .
    Name of SampleConsignorM...
    Name of SampleConsignorManufacturerTest MethodCriterionAppearanceTest DateSample NumberTest ItemsConclusionUnited Nations "Recomenndations on the TRANSPORT OF DANGEROUS GOODS"Black rectangular parallelepiped2008/11/20 - 2008/12/1924Altitude simulation, Th...
  • 2 .
    Presence ofchange----T2:T...
    Presence ofchange----T2:Thermal Shock  (Repetition of high temp.and low temp.)・Crimped part, Gasket (Cell)・Gas Release Vent, Cell Case (Cell)・Finished state of Wound Electrodes (Cell)・Pack (Plastic) Case・Holding Member(Insulator, Insulation Tape, Both Side...
  • 3 .
    (Manual of Tests and Cri...
    (Manual of Tests and Criteria ST/SG/AC.10/11/Rev.4, PartIII,sub-section 38.3)7.56 gAS10E36May.27.2010Nominal voltageWatt-hour rating Lithium ion battery Specification:::Customer Model For battery onlyFor cell onlyE1004664PassPassPassPassPassPassPass−S...
  • 4 .
    7.56 gAS10E36May.27.2010...
    7.56 gAS10E36May.27.2010Nominal voltageWatt-hour rating Lithium ion battery Specification:::Customer ModelE1004664Sanyo Product CodeSanyo ModelF138608043UR18650-3-T0664Certificate of Package Drop Test for Lithium ion battery11.1 V94 Wh
  • 5 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Altitude simulation (T1) P.3/102.Test Purpose: This test simulates air transport under low-pressure conditions.3.Test Procedure: Test cells and batteries shall be stored at a pressure of 11.6kPa...
  • 6 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Thermal Test (T2) P.4/102.Test Purpose: This test assesses cell and battery seal integrity and internal electrical connections. The test is conducted using rapid and extreme temperature changes...
  • 7 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Vibration (T3) P.5/102.Test Purpose: This test simulates vibration during transport.3.Test Procedure: Cells and batteries are firmly secured to the platform of the vibration machine without disto...
  • 8 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Shock (T4) P.6/102.Test Purpose: This test simulates possible impacts during transport.3.Test Procedure: Test cells and batteries shall be secured to the testing machine by means of a rigid mount...
  • 9 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: External short circuit (T5) P.7/102.Test Purpose: This test simulates an external short circuit.3.Test Procedure: The cell or battery to be tested shall be temperature stabilized so that its exte...
  • 10 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Impact (T6) P.8/102.Test Purpose: This test simulates an impact.3.Test Procedure: The test sample cell or component cell is to be placed on a flat surface. A 15.8mm diameter bar is to be placed ac...
  • 11 .
    UN Test Data (Mod...
    UN Test Data (Model:3UR18650-3-T0664)1.Test Item: Overcharge (T7) P.9/102.Test Purpose: This test evaluates the ability of a rechargeable battery to withstand an overcharge condition.3.Test Procedure: The charge current shall be twice the manufac...