AS2010B 30ARevision 0.03/ 9Model : AS2010B 6C_30A(black)Pack Test Program■■■■Tests T-1 through T-5 shall be conducted in sequenc e with the same call■■■■For test 6, test should be conducted for cells in a pack 5- -5-Not exceed 170℃℃℃℃, No disassembly No rupture, No fire within 6HrsFlat surface, 15.8mm bar, weight:9.1Kg, Height : 61±2.5cmT-6 Impact44100%No disassemblyNo fire within 7days- - - 4Current: 2xRapid charge currentCharge Voltage 18V Under: 2 x V (Max Voltage) or 22VCharge Voltage 18V Over:1.2 x V (Max Voltage) , Time 24hrsT-7 OverchargeNot exceed 170℃℃℃℃, No disassembly No rupture, No fire within 6HrsWire: Less 0.1ohm,Case temp. : 55±2℃℃℃℃for 1Hr or temp. returnHalf-sine shock of peak acceleration 150g, duration 6ms 3(pos.)shocks →→→→3(neg.)shocks, 3direction, Total 18shocks7Hz →→→→200Hz →→→→7Hz in15min,12cycle for 3Hr, 3 direction75±2℃℃℃℃for 6Hr ↔↔↔↔-40±2℃℃℃℃for 6Hrs (Transfer time : 30min), 10cycle4 4 - 4No mass loss (not exceed 0.1%)No leakage, No ventingNo disassemblyNo rupture, No fire OCV > 90% of the initial voltage11.6 kPa for 6Hr at 20±5℃℃℃℃T-1 Altitude SimulationT-2 Thermal TestT-3 VibrationT-4 ShockT-5 External short circuit0%0%50%100%50 cycledFreshCriteria Test MethodTest Item

参考になったと評価
  3人が参考になったと評価しています。

その他の取扱説明書
3148 view
4850 view
39922 view
887 view
925 view
もっと見る

このマニュアルの目次

  • 1 .
    Revision 0.0Test Report o...
    Revision 0.0Test Report of IATA/UN Transportation Test Report of IATA/UN Transportation revised by the Recommendations on the Transport of Dangerous Goorevised by the Recommendations on the Transport of Dangerous Goods,Manual of Test and CriteriaMobile E...
  • 2 .
    AS2010B 30ARevision 0.02/...
    AS2010B 30ARevision 0.02/ 9Model : AS2010B 6C_30A(black)Product SpecificationModel Name : AS2010B 6C_30A(black))Nominal voltage : 11.1 VRated capacity : 6000 mAhLithium equivalent content : 5.31 gDate of issue : 2
  • 3 .
    AS2010B 30ARevision 0.03/...
    AS2010B 30ARevision 0.03/ 9Model : AS2010B 6C_30A(black)Pack Test Program■■■■Tests T-1 through T-5 shall be conducted in sequenc e with the same call■■■■For test 6, test should be conducted for cells in a pack 5- -5-Not exceed 170℃℃℃℃, No disassembly No...
  • 4 .
    AS2010B 30ARevision 0.04/...
    AS2010B 30ARevision 0.04/ 9Model : AS2010B 6C_30A(black)T-1~T-5) Transportation Test (Fresh Pack)●●●●Sample : 100% Charged - 4 Ea , 0% Charged - 4 Ea After T-5Weight OCV Weight Mass Loss OCV Weight Mass Loss OCV Weight Ma ss Loss OCV Weight Mass Loss ...
  • 5 .
    AS2010B 30ARevision 0.05/...
    AS2010B 30ARevision 0.05/ 9Model : AS2010B 6C_30A(black)T-1~T-5) Transportation Test (50Cycled Pack)●●●●Sample : 50Cycled : 100% Charged - 4 Ea , 0% Charged - 4 EaAfter T-5Weight OCV Weight Mass Loss OCV Weight Mass Loss OCV Weight Ma ss Loss OCV Weigh...
  • 6 .
    AS2010B 30ARevision 0.06/...
    AS2010B 30ARevision 0.06/ 9Model : AS2010B 6C_30A(black)T-6) Impact Test (ICR18650-30A)●●●● Test method: Drop 9.1kg mass from 61cm height with 15.8mm diameter bar.●●●● Sample : Fresh Cell - 5 Ea / 50 cycled Cell - 5 Ea●●●● Test results: All Leakage on...
  • 7 .
    AS2010B 30ARevision 0.07/...
    AS2010B 30ARevision 0.07/ 9Model : AS2010B 6C_30A(black)T-7) Over charge Test● Test method : 6[A], 24[V]0.5C discharge → 24Hrs charge →7days storage● Sample Fresh Pack : (100% charged) - 4Ea50cycled Pack : (100% charged) - 4Ea● Test results : All no Le...
  • 8 .
    AS2010B 30ARevision 0.08/...
    AS2010B 30ARevision 0.08/ 9Model : AS2010B 6C_30A(black)P-1) Packaging Drop (1.2m) Test
  • 9 .
    AS2010B 30ARevision 0.09/...
    AS2010B 30ARevision 0.09/ 9Model : AS2010B 6C_30A(black)P-1) Packaging Drop (1.2m) Test