UN Test Data (Model:3UR18650-2-T0627)1.Test Item: Overcharge (T7)P.9/102.Test Purpose: This test evaluates the ability of a rechargeable battery to withstand an overcharge condition.3.Test Procedure: The charge current shall be twice the manufacturer's recommended maximum continuous charge current. The minimum voltage of the test shall be as follows: (a) when the manufacturer's recommended charge voltage is not more than 18V,the minimum voltage of the test shall be the lesser of two times the maximum charge voltage of the battery or 22V. (b) when the manufacturer's recommended charge voltage is more than 18V, the minimum voltage of the test shall be 1.2 times the maximum charge voltage. Tests are to be conducted at ambient temperature. The duration of the test shall be 24 hours. SANYO Internal Procedure: Min.Charge Voltage: Charge Current:4.Test Requirements: There is no disassembly and no fire within seven days of the test.5.Test Date: 2010/1/12-2010/1/206.Test DataResult Judgement1 PASS2 PASS3 PASS4 PASS5 PASS6 PASS7 PASS8 PASSNotes: D-Disassembly, F-Fire, 0-No disassembly & no fire000 At firstcycle in fullychargedstates0PASS000After 50cyclesending infullychargedstates022V3.6ABattery No. Event